Clean. Stable. Compliant.
Infrastructure for Medical AI.

Healthcare compute infrastructure must be thermally stable, physically clean, acoustically controlled, and continuously available.

Discuss Your Healthcare Infrastructure→

Why conventional data centers fall short.

Life-Critical Power Continuity

AI diagnostics and patient monitoring cannot tolerate unplanned downtime. Redundancy must meet clinical-grade availability.

Medical Data Sovereignty

HIPAA, GDPR, and institutional governance constrain where patient data can be processed — requiring on-premises infrastructure.

Environmental Standards

Noise, particulate, and vibration standards in clinical-adjacent environments exceed what colocation infrastructure can meet.

EPC Solution

Medical-grade AI infrastructure.

CoolSpace delivers modular infrastructure with closed-loop hydro-cooling that produces zero water vapor, 2N redundancy across all critical subsystems, and acoustic design for clinical environments. Indoor CoolPod units deploy within existing hospital machine rooms — no new construction required. Power continuity is maintained via integrated UPS and optional diesel generator with automatic transfer switch.

· Zero water vapor — closed-loop design maintains clinical particulate standards · 2N power and cooling redundancy as standard engineering baseline · On-premise deployment — medical data never leaves the facility boundary
CoolSpace modular data center infrastructure designed for healthcare-adjacent deployment

Built for healthcare operating standards.

Zero-Vapor Closed-Loop Cooling

Closed-loop hydro-cooling produces no water vapor, maintaining particulate and humidity standards required in clinical-adjacent environments.

2N Power and Cooling Redundancy

CDU, UPS, power distribution, and cooling are configured in 2N redundancy as standard, maintaining continuity during planned and unplanned maintenance.

On-Premise Medical Data Processing

Indoor modular infrastructure deploys within existing hospital facilities for HIPAA-compliant, on-premise processing of patient data.

Acoustic-Grade Enclosure Design

CoolPod indoor units are designed for building-interior deployment with acoustic profiles appropriate for clinical environments.

Infrastructure Parameters

Healthcare compute block specifications.

Cooling MethodClosed-loop hydro-cooling — zero water vapor
PUE (Free Cooling)≤ 1.05
PUE (Standard Config)≤ 1.25
Water / Vapor OutputZero — no evaporative or vapor discharge
Redundancy2N CDU · 2N UPS · 2N power distribution
Battery OptionsLithium-ion (standard) / Lead-acid (optional)
Power ContinuityIntegrated ATS + UPS + optional diesel generator
Form FactorIndoor CoolPod Series — deploys in existing buildings
IT Load Range100 kW (CoolPod pilot) → 48 MW+ (campus scale)
Data SovereigntyOn-premise — data does not leave facility boundary
Compatible HardwareH100 / H200 / GB200 / GB300 and equivalent
Hospital IT room with compact server racks and monitoring screens
Radiologist reviewing AI-assisted medical imaging on a diagnostic display

Healthcare data center infrastructure · AI-assisted medical imaging

Deploying AI in a healthcare environment?

Share your facility constraints and workload profile — CoolSpace engineering will return a configured proposal within 5 business days.